Rossmax Ear Thermometer RA600

$51.95

This Rossmax infrared ear thermometer is intended for measuring human body temperature; while is not intended as a substitute for consultation with your physician. This thermometer has been clinically tested in the hospital based on the regulatory standard protocol and proven to be safe and accurate when used in accordance to the operating instruction manual.

Product Feature:

  • Highest accuracy by rotating in 3” Scanning Mode or 1” measurement
  • Multiple-Use PLUG & SECURE Probe Cover (Clean the Probe Cover with alcohol after every use)
  • Ear temperature
  • Fever Alarm
  • 9 memories
  • °C / °F switchable
  • Backlight
  • Auto shut-off
  • Low battery indicator
  • Self-diagnosis for malfunction

Pack Contents:

  • 1 x Thermometer
  • 5 x Multiple-Use Probe Cover
  • Storage Case
  • Batteries
  • Instruction Manual

Only 3 left in stock

Description

Directions

  1. To achieve accurate readings, make sure a clean Probe Cover is in place before each measurement and the ear canal is clean.
    a. Install the Probe Cover by clockwise rotating; then fix it.
    b. Remove the Probe Cover by anti-clockwise rotating; then release it.
  2. Press the “On/Off/Memory” button, the thermometer is ready for use after the ear icon is flashing, two beeps are sounded, and three dash segments are appeared.
  3. As the ear canal is slightly curved, you have to pull the ear slight up and backwards before inserting the probe. This is important so that the tip of the Probe Cover can be pointed directly at the eardrum.
    a. Before measurement, the correct installation of the Probe Cover ensures an accurate measurement.
    b. Replace with a new Probe Cover after approx. 30 times of use to ensure an accurate reading.
    c. This thermometer must only be used with Rossmax Probe Covers, other covers can lead to inaccuracy. If running out of Probe Covers, please contact the original seller or distributor for buying new Probe Covers. Do never measure without Probe Cover or with a broken Probe Cover.
  4. Measuring the ear temperature:
    • With 1” Measurement: Use the index finger to trigger, by pressing “Start” button, a long beep will be sounded when measurement is done.
    • With 3” Scanning Mode: For highest accuracy always use 3” Scanning Mode. Use the index finger to trigger, press and hold the “Start” button for 3 seconds to take measurement. Gently rotate the probe in the entire ear canal in order to find the highest temperature. Release the “Start” button until hearing a long beep sound and the measurement is completed.
  5. For the next measurement, ensure that there is no breakage or stains of Probe Cover before each measurement, otherwise replace the Probe Cover with a new one.
  6. Power off: If left idle for more than 1 minute, device will automatically shut off for extending battery life. Or press “On/Off/Memory” button for at least 3 seconds to turn the device off.
  7. Fever alarm: When the measuring temperature is higher than 37.5 °C(99.5°F), the reading will flash, the backlight will be enabled, and 4 short beeps will be sounded. If measuring temperature is higher than 42.2 °C(108°F), the display will show “Hi”, the backlight will be enabled, and 4 short beeps will be sounded.
    a. It is recommended that you measure 3 times with the same ear within a short period of time. If the 3 consecutive measurements are different, select the highest temperature; or do a 3” Scanning Mode measurement to find highest temperature.
    b. To avoid the cross contamination risk, please clean the probe and Probe Cover according to “ Clean and Storage” section
    after each use.

Enabling or disabling the beep sound

  1. Turn off the device.
  2. Hold down the “Start” button, then press and hold the“ON/OFF/Memory” button until the LCD shows °C.
  3. Press the “ON/OFF/Memory” change beep sound from on to off, then release the “ON/OFF/Memory” button.
  4. After 6 seconds without changing, the beep On/Off setting will be completed, and the unit will be entered into the measurement mode.

Switching between temperature scale Fahrenheit and Celsius
To change the Unit from °C to °F:

  1. Turn off the device.
  2. Hold down the “Start” button, then press and hold the“ON/OFF/Memory” button until the LCD shows °C.
  3. Press the “Start” to change the °C to °F, then release the “Start” button.
  4. During the setting adjustment, each old or new temperature scale setting will be flashing for 6 seconds. After 6 seconds without changing, the temperature scale adjustment will be completed, and the unit will be entered into measurement mode.

Cleaning and Storage

The clean and intact probe cover is the major factor of accurate reading, and the probe is the most delicate of the thermometer. Use with care when cleaning it to avoid damage.

  1. Please use the cotton swab with the Alcohol to clean the lens (on the inside of the probe) and use the Alcohol pad to clean the probe cover.
  2. Allow the probe and probe cover to fully dry for at least 5 minutes.
    a. Please check the device if it falls and damages. If you can’t make sure of it, please send the complete device to the nearest retailer for recalibration.
    b. Keep the unit dry and away from any liquid and direct sunlight. The probe should not be submerging into liquids.
    c. Please check the probe cover, ensure that there is no breakage or stains of probe cover before each measurement.

Caution

  1. Besides the oral temperature, the body temperature measured by ear may be different from measurements taken by rectal or axillary. Therefore, there is no any meaning to compare them. Take the temperature periodically to find out the normal ear temperature reading , then use that reading as the basis for comparison with any measurement taken when you suspect a fever.
  2. This thermometer is designed for ear temperature measurement. Do not use this thermometer for other body site measurement.
  3. Keep the unit dry and away from where it might be exposed to moisture, liquids, direct sunlight, high temperature, high humidity, or excessive dust.
  4. This device is not shock-protected. Do not drop, heavily pressure the unit or fall from high place.
  5. Do not bend the device.
  6. Do not disassemble or make modifications on the device.
  7. Please do not dispose of the product in the household waste at the end of its useful life. Disposal can take place at your local retailer or at appropriate collection points provided in your country.
  8. Do not boil the probe.
  9. Do not use the device if it operates abnormally or error massage is showed.
  10. Do not use thinner or benzene to clean the device.
  11. Wipe the device clean before storing.
  12. When taking the device from storage below or above 10~ 40°C(50~104°F), place it in 10~ 40°C(50~104°F) temperature range for at least 30 minutes before use.
  13. Remove the battery if this device is not used for a period of time.
  14. If this device is used according to the operation instruction, periodic re-calibration is not required. If you still have questions, please send the complete device to dealers.
  15. Do not use this device for diagnosis or treatment of any health problem on disease. Measurement results are for reference only. Contact your physician if you have or suspect any medical problems. Do not change your medications without the advice of your physician or healthcare professional.
  16. This device may not meet its performance specification if stored or used outside temperature and humidity ranges specified in specifications.
  17. Battery should neither be charged nor placed into the extreme environment, or it may explode.
  18. The thermometer contains small parts (ex: battery, etc.) that can be swallowed by children. Therefore never leave the thermometer unattended to children.
  19. After wearing the probe cover, the ear thermometer probe must be vertically and snugly inserted into the ear channel so as to get the correct temperature reading.
  20. Be sure to consult a doctor if you feel that your health is in poor condition.
  21. Do not judge your health only on the presence or absence of a fever.
  22. Do not service or maintain device while in use.

Brand

Rossmax

Rossmax, a leader in the global healthcare market, is committed to developing and supplying premium products and solutions with supreme technologies on a top quality level.

The business fields are PREVENTION, MONITORING, THERAPY. The product and service portfolio consists of healthcare products in the field of Hypertension, Respiratory Care, Blood Glucose Management, Fever Management, Fitness, Obesity, Hot & Pain Therapy, Wound Healing as well as Sleep Disorder. All products are distributed in more than 90 countries and are clinically validated and approved based on latest quality standards. With the only fully integrated factory in the industry, Rossmax is very proud on their world class manufacturing capabilities and end-to-end process controls. From pioneering research and product development to highly efficient manufacturing, shipping and logistics, the operational excellence is a crucial key to the success.

Additional information

Barcode

Product Code

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.